Thông số kỹ thuật Bộ điều khiển động cơ Servo MR-J2S-CL Servo Driver Amplifier, điều khiển 1 trục:
Servo amplifier model MR-J2S- | 10CL | 20CL | 40CL | 60CL | 70CL (-UM) |
100CL | 200CL | 350CL | 500CL | 700CL (-UM) |
10CL1 | 20CL1 | 40CL1 | ||
Power supply | Voltage/frequency (Note 1) | 3-phase 200 to 230VAC 50/60Hz or 1-phase 230VAC 50/60Hz (Note 2) |
3-phase 200 to 230VAC 50/60Hz (Note 2) | 1-phase 100 to 120VAC 50/60Hz (Note 2) |
|||||||||||
Permissible voltage fluctuation | 3-phase 200 to 230VAC: 170 to 253VAC 1-phase 230VAC: 207 to 253VAC |
3-phase 170 to 253VAC | 1-phase 85 to 127VAC | ||||||||||||
Permissible frequency fluctuation | ±5% maximum | ||||||||||||||
Control system | Sine-wave PWM control/current control system | ||||||||||||||
Dynamic brake | Built-in (Note 3) | ||||||||||||||
Safety features | Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servo motor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection, overspeed protection, excess error protection | ||||||||||||||
Command method | Program | Operating specification | Program language (programmed by the setup software) Program capacity: 120 steps | ||||||||||||
Input positioning command | Set by the program language One-point feed length setting range: ±1 (µm) to ±999.999 (mm) | ||||||||||||||
Input speed command | A servo motor speed, acceleration and deceleration time constants, and S-pattern acceleration and deceleration time constants are set by the program language. The S-pattern acceleration and deceleration time constants can be set by parameter No. 14 as well. |
||||||||||||||
System | Signed absolute value command system, and signed incremental value command system | ||||||||||||||
Operating mode | Program operation mode | Depends on the setting of the program language | |||||||||||||
Manual operation mode | JOG | Inches upon contact input or RS-422 (RS-232C) communication based on speed commands set by a parameter. | |||||||||||||
Manual pulse generator | Manual feed by manual pulse generator. Command pulse ratio: Selectable ✕1, ✕10, or ✕100 by the parameter. |
||||||||||||||
Manual home position return mode | Dog system | Returns to home position upon Z phase pulse count after passing through near-point dog. Direction for return to home position selectable. Home position shift amount and home position address selectable. Automatic retreat on dog back to home position and automatic stroke retreat function. |
|||||||||||||
Count system | Returns to home position upon encoder pulse count after touching near-point dog. Direction for return to home position selectable. Home position shift amount and home position address selectable. Automatic retreat on dog back to home position and automatic stroke retreat function. |
||||||||||||||
Data set system | Returns to home position without dog. Set any position as the home position using manual operation or the like. Settable home position address. |
||||||||||||||
Stopper system | Returns to home position upon hitting end of stroke. Direction for return to home position selectable. Home position address settable. |
||||||||||||||
Ignore home (Servo-on position as home position) | Uses position where the servo on signal (SON) becomes ON as home position. Settable home position address. | ||||||||||||||
Dog system rear end reference | Returns to home position with respect to the rear end of a near-point dog. Direction for return to home position selectable. Home position shift amount and home position address selectable. Automatic retreat on dog back to home position and automatic stroke retreat function. |
||||||||||||||
Count system front end reference | Returns to home position with respect to the front end of a near-point dog. Direction for return to home position selectable. Home position shift amount and home position address selectable. Automatic retreat on dog back to home position and automatic stroke retreat function. |
||||||||||||||
Dog cradle system | Returns to home position with respect to the front end of a near-point dog by the first Z-phase pulse. Direction for return to home position selectable. Home position shift amount and home position address selectable. Automatic retreat on dog back to home position and automatic stroke retreat function. | ||||||||||||||
Other functions | Absolute position detection, backlash correction, overtravel protection by the external limit switch, software stroke limit, override by external analog control |
||||||||||||||
Structure | Self-cooling, open (IP00) | Fan cooling, open (IP00) | Self-cooling, open (IP00) | ||||||||||||
Environment | Ambient temperature | 0 to 55°C (32 to 131°F) (non freezing), storage: –20 to 65°C (–4 to 149°F) (non freezing) | |||||||||||||
Ambient humidity | 90% RH maximum (non condensing), storage: 90% RH maximum (non condensing) | ||||||||||||||
Atmosphere | Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust | ||||||||||||||
Elevation | 1000m (3280ft) or less above sea level | ||||||||||||||
Vibration | 5.9m/s2 maximum | ||||||||||||||
Mass (kg [lb]) | 0.7 (1.5) | 0.7 (1.5) | 1.1 (2.4) | 1.1 (2.4) | 1.7 (3.7) | 1.7 (3.7) | 2.0 (4.4) | 2.0 (4.4) | 4.9 (10.8) | 7.2 (15.9) | 0.7 (1.5) | 0.7 (1.5) | 1.1 (2.4) |
Kết hợp ghép đôi Bộ điều khiển Servo MR-J2S điện áp 220 VAC 1 pha hoặc 3 pha với động cơ Servo Motor
Servo Driver Symbol | HC-KFS | HC-MFS | HC-SFS | HC-LFS | HC-RFS | HA-LFS | HC-UFS | |
MR-J2S-A / A1 / B / CP / CL | 10 | 053, 13 | 053, 13 | — | — | — | — | 13 |
MR-J2S-A / A1 / B / CP / CL | 20 | 23 | 23 | — | — | — | — | 23 |
MR-J2S-A / A1 / B / CP / CL | 40 | 43 | 43 | — | — | — | — | 43 |
MR-J2S-A / A1 / B / CP / CL | 60 | — | — | 52, 53 | 52 | — | — | — |
MR-J2S-A / A1 / B / CP / CL | 70 | 73, 46, 410 | 73 | — | — | — | — | 72, 73 |
MR-J2S-A / A1 / B / CP / CL | 100 | — | — | 81, 102, 103 | 102 | — | — | — |
MR-J2S-A / A1 / B / CP / CL | 200 | — | — | 121, 201, 152, 202, 153, 203 |
152 | 103, 153 | — | 152 |
MR-J2S-A / A1 / B / CP / CL | 350 | — | — | 301, 352, 353 | 202 | 203 | — | 202 |
MR-J2S-A / A1 / B / CP / CL | 500 | — | — | 502 | 302 | 353, 503 | 502 | 352, 502 |
MR-J2S-A / A1 / B / CP / CL | 700 | — | — | 702 | — | — | 601, 701M, 702 |
— |
MR-J2S-A / A1 / B / CP / CL | 11K | — | — | — | — | — | 801, 12K1, 11K1M, 11K2 |
— |
MR-J2S-A / A1 / B / CP / CL | 15K | — | — | — | — | — | 15K1, 15K1M, 15K2 |
— |
MR-J2S-A / A1 / B / CP / CL | 22K | — | — | — | — | — | 20K1, 25K1, 22K1M, 22K2 |
— |
MR-J2S-A / A1 / B / CP / CL | 30K | — | — | — | — | — | 30K1, 30K1M, 30K2 |
— |
MR-J2S-A / A1 / B / CP / CL | 37K | — | — | — | — | — | 37K1, 37K1M, 37K2 |
— |